INSTALLATION:
Brick to Block Application
Mortar Joint Entry



Step 1:
Drill 5mm pilot hole using rotary percussion drill (3-jaw chuck type) through mortar joint into back-up block (approx. 3").



Step 2:
Load SPIRA-LOK™ Helical Wall Tie System into dry set tool which is mounted into electric hammer drill (S.D.S. type).



Step 3:
Drive SPIRA-LOK™ Helical Wall Tie System Helical Tie through mortar joint into block back-up. Dry set tool will recess tie below face of masonry approximately 3/8".



Step 4:
Installed tie.